Cytometry Instrumentation
Cytometers are quantitative microscopes – the light emitted, reflected, or refracted from small things is imaged onto photomultiplier tubes, photo-diodes, avalanche diodes, or CCD camera and the amplified resulting electrical signal is converted to digital form and subsequently processed by the cytometer's hardware and software. The result is a list of data for each cell sampled from a population. Since all cell populations are heterogeneous or asynchronous (despite efforts to purify and synchronize), multiparametric cytometer data are correlated in a meaningful way within samples.
Cell Sorting
- BD Biosciences Aria
- 3 lasers; 9 color (blue, green, orange, red, far-red) emission
- Compatible dyes: Hoechst 33342, DAPI, Pacific Blue, Pacific Orange, Fluorescein/A488, GFP, PI, AO, 7AAD, PE, A555, Cy3, YFP, PE-Cy5, PE-Cy5.5, PE-Cy7,PerCp, PerCp-Cy7, A647, A700, AP, AP-Cy7
- Four way sorting; multi-well plate sorting. Sort speed 25,000/s
- ICyte Reflection
- 5 lasers (choice of 2); 4 color (blue, green, orange, red, far-red) emission
- Compatible dyes: Hoechst 33342, DAPI, Pacific Blue, Pacific Orange, Fluorescein/A488, GFP, PI, AO, 7AAD, PE, A555, Cy3, YFP, PE-Cy5, PE-Cy5.5, PE-Cy7, PerCp, PerCp-Cy7, Texas Red, RFP, A647, A700, AP, AP-Cy7
- Four way sorting. Flexible, high speed. Sort speed 50,000/s
Flow Cytometry
- Millipore Guava
- 1 blue laser; 2 color (green and red) emission
- Compatible dyes: Fluorescein/A488, PI, 7AAD
- This cytometer is mainly used for live/dead cell counting and data are output as events per ml. Does not have light scatter parameters.
- Beckman Coulter XL
- 1 blue laser; 4 color (green, orange, red, far red) emission
- Compatible dyes: Fluorescein/A488, GFP, PI, AO, 7AAD, PE, A555, Cy3, YFP, PE-Cy5, PE-Cy5.5, PE-Cy7, PerCp, PerCp-Cy7
- BD Biosciences LSR 2
- 5 lasers; 14 color (blue, green, orange, red, far red) emission
- Compatible dyes: Hoechst 33342, DAPI, A350, Pacific Blue, Pacific Orange, Fluorescein/A488, GFP, PI, AO, 7AAD, PE, A555, Cy3, YFP, PE-Cy5, PE-Cy5.5,
PE-Cy7, PerCp, PerCp-Cy7, A647, A700, AP, AP-Cy7
Imaging Cytometry
- Compucyte iCyte laser scanning cytometer (LSC)
- 3 lasers; 8 color (blue, green, orange, red) emission
- Compatible dyes: Hoechst 33342, DAPI, Pacific Blue, Pacific Orange, Fluorescein/A488, GFP, PI, AO, 7AAD, PE, A555, Cy3, YFP, PE-Cy5, PerCp, A647, AP
- This platform accepts chamber slides, standard culture dishes with coverslipped windows (Labtek); optical grade multiwall plates
- Amnis Image Stream flow cytometer
- 3 lasers; X color (blue, green, orange, red) emission
- Compatible dyes: Hoechst 33342, DAPI, Pacific Blue, Pacific Orange, Fluorescein/A488, GFP, PI, AO, 7AAD, PE, A555, Cy3, YFP, PE-Cy5, PE-Cy5.5, PE-Cy7, PerCp, PerCp-Cy7, A647, AP